Sign In | Join Free | My spintoband.com
China Changzhou DLX Alloy Co., Ltd. logo
Changzhou DLX Alloy Co., Ltd.
Verified Supplier

5 Years

Home > Thermocouple Extension Wire >

Type K / J / E / N / T / R / S / B Thermocouple Extension Cable With PVC Sheath

Changzhou DLX Alloy Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Type K / J / E / N / T / R / S / B Thermocouple Extension Cable With PVC Sheath

Brand Name : DLX

Model Number : Type k Thermocouple extension wire

Certification : CE,ROHS

Place of Origin : China

MOQ : 5

Payment Terms : L/C, T/T, Western Union, MoneyGram

Supply Ability : 300 tons per month

Delivery Time : 5-21 days

Packaging Details : Spool package with Carton box, Coil package with polybag

Product name : Thermocouple K extension wire

Color : bright

Certificate : ISO9001

Temperature range : 32 to 392F (0 to 200C)

EMF tolerance : +/- 2.2C or +/- .75%

Grade : Extension Grade Type K

Positive : Ni-cr

Negative : Ni-si

Special Limits of Error : +/- 1.1C or 0.4%

Contact Now

Type K / J / E / N / T / R / S / B Thermocouple Extension Cable with PVC Sheath for -20~100℃ Temperature Range

Thermocouple compensation wire temperature measurement principle

The function of compensating wires for thermocouples is to extend the thermoelectric electrode, that is, move the cold end of the thermocouple, and connect it with the display instrument to form a temperature measurement system. The product is mainly used in various temperature measurement devices and has been widely used in departments such as petroleum, chemical, metallurgy, and power.

Generally speaking, thermocouples may be several tens of meters away from the thermometer, and the temperature at the cold end (outlet) of the thermocouple is different from the ambient temperature of the thermometer (even up to several tens of degrees).

If ordinary copper wires are used, according to the principle of thermocouples, the junction will generate thermoelectric potential, which will result in measurement errors.

The voltage drop problem of long-distance transmission wires is due to the high input impedance of the thermometer, the small transmission current (micro A level) generated by the thermocouple (millivolt level), and the small voltage drop loss on the wire, which is generally within the error range. So there is a thermocouple transmitter that inputs thermocouple signals and outputs 4-20mA, which allows for long-distance transmission without compensating for wires.

If a compensating wire is used (which must match the thermocouple graduation number), the metal material used can generate the smallest possible thermoelectric potential at the wiring point and minimize temperature measurement errors as much as possible. That is to say, move the cold end of the thermocouple to the thermometer.

Equipped with thermoelectric Even graduation number

common(G)
heat resistant(H)
Common
Precision(S)
Common
Precision(S)
S
SC-G
SC-GS
SC-H
--
N
NC-G
NC-GS
NC-H
NC-HS
K
NC-G
NC-GS
NC-H
--
KC2-G
KG2-GS
KC2-H
KC2-HS
KX-G
KX-GS
KX-H
KX-HS
E
EX-G
EX-GS
EX-H
EX-HS
J
JX-G
JX-GS
JX-H
JX-HS
T
TX-G
TX-GS
TX-H
TX-HS
  • ​Standards
ASTM ANSI IEC DIN BS NF JIS GOST
(American Society for Testing and Materials) E 230 (American National Standard Institute) MC 96.1 (European Standard by the International Electrotechnical Commission 584)-1/2/3 (Deutsche Industrie Normen) EN 60584 -1/2 (British Standards) 4937.1041, EN 60584 - 1/2 (Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324 (Japanese Industrial Standards) C 1602 - C 1610 (Unification of the Russian Specifications) 3044

Working Temperature Range

Diameter/mm Long time Working temperature /ºC Short period Working temperature /ºC
0.3 700 800
0.5 800 900
0.8,1.0 900 1000
1.2,1.6 1000 1100
2.0,2.5 1100 1200
3.2 1200 1300

Thermocouple No. indexing Compensation wire type Usag Classification Measuring junction temperature / ℃ standard EMF value/μV Precision grade General grade
Tolerance μV Thermal EMF range μV Tolerance μV Thermal EMF range μV
SorR SC or RC G 100 646 ±30 616~676 ±60 586~706
H 100 646 - - ±60 586~706
200 1 1441 - - 1.381~1 501
K KX,KCA G -25 -968 ±40 -924~-1 012 ±80 -880~-1 056
or KCB 100 4 096 4 052~4 140 4 008~4 184
H -25 -968 ±40 -924~-1 012 ±88 -880~-1 056
100 4 096 4 052~4 140 4 008~4 184
200 8 138 8 094~8 182 8 050~8 226
N NX or NC G -25 -646 ±43 -603~-689 ±86 -560~-732
100 2 774 2 731~2 817 2 688~2 860
H -25 -646 ±43 -603~-690 ±86 -560~-732
100 2 774 2 731~2 817 2 688~2 860
200 5 913 5 870~5 956 5 827~5 999
E EX G -25 -1 432 ±81 -1 351~-1 513 ±138 -1 294~-1 570
100 6 319 6 238~ 6400 6 181~6 457
H -25 -1 432 ±81 -1 351~- 1513 ±138 -1 294~-1 570
100 6 319 6 238~6 400 6 181~6 457
200 13 421 13 340~13 502 13 283~13 559
J JX G -25 -1 239 ±62 -1 177~-1 301 ±123 -1 116~-1 362
100 5 269 5 207~5 331 5 146~5 392
H -25 -1 239 ±62 - 177~-1 301 ±123 -1 116~-1 362
100 5 269 5 207~5 331 5 146~5 392
200 10 779 10 717~10 841 10 656~10 902
T TX G -25 -940 ±30 -910~-970 ±60 -850~-1 000
100 4 279 4 249~4 309 4 189~4 339
H -25 -940 ±48 -892~-988 ±90 -850~-1 030
100 4 279 4231~4 327 4 189~4 369
200



Product Tags:

Type B Thermocouple Extension Cable

      

PVC Sheath Thermocouple Extension Cable

      

Bright Thermocouple Extension Wire

      
Wholesale Type K / J / E / N / T / R / S / B Thermocouple Extension Cable With PVC Sheath from china suppliers

Type K / J / E / N / T / R / S / B Thermocouple Extension Cable With PVC Sheath Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Changzhou DLX Alloy Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 